Strain Gauge
DESCRIPTION
1.Application of this trainer is to measure mechanical and Terminal quantities (like strain, force, pressure, torque, displacement, acceleration, frequency, temperature and heat flux).
2.Zero balancing facility through adjustment potentiometer.
3.Digital display to take error free reading with 31/2 digital Red LED display of 200mv FSD to read up to +/- 1999 micro strain.
4.Cantilever beam with stainless steel.
5. Beam 0.25cm thick, 2.8cm width, 22cm length.
SPECIFICATIONS
DISPLAY RANGE : 31/2 digit RED LED display of 200 mV FSD to read up to +/-1999 microstrain
GAUGE FACTOR SETTING : 2.1
BALANCE : Potentiometer to set zero on the panel.
BRIDGE EXCITATION:10VDC
BRIDGE CONFIGURATIONS : Full Bridge
MAX. LOAD : lKg.
POWER : 230 V +/- 10% at 50Hz. with perfect grounding.
: All specifications are nominal or typical at 23° C unless noted.
CANTILEVER BEAM SPECIFICATION
MATERIAL : Stainless Steel
BEAM THICKNESS (t) : 0.25 cm
BEAM WIDTH ( b) : 2.8 cm
BEAM LENGTH (Actual) : 22 cm
YOUNGS MODULUS (s ) : 2 X 106 Kg / cm2
STRAIN GAUGE : Foil type gauge
GAUGE LENGTH (1) : 5 mm
GAUGE RESISTANCE (R) : 300 Ohms.
GAUGE FACTOR ( g) : 2.01
|